Input |
• Rated input voltage |
110Vdc nom. 70Vdc min. 165Vdc max. |
|
• Input protection |
• External fuse T 4A required for safety • Input overvoltage comply to EN50155 and St.n°306158 • Inrush current limitation |
Output |
• Remote sense compensation |
S+ and S- must be connected to Vo and Go if not used |
|
• Output power (max) |
132W |
|
• Parallel connection |
The unit can be paralleled for application requiring greater than 10A |
|
• Test points |
Red test-point Vo Black test-point Go |
|
• Output protections |
• Short circuit protection • Overload protection • Output overvoltage protection • Over temperature protection (over110°C) • EMI radiated noise compatibility |
General Features |
• Dieletric withstand voltage |
• (input=output) - chassis : 500Veff 50Hz 1min. |
|
• Isolation |
• (input=output) - chassis : 500Vdc |
|
• See table for |
• Output voltage and current • Output tolerance with load (0÷Inom), line(70÷165V) and temp.(-25°C÷70°C): ±3.75% • Output ripple and noise |
|
• Cooling |
Natural convection |
|
• Operating indicator |
• Green led Vout OK |
|
• Operating temperature |
-25 to 70°C |
|
• Storage temperature |
-55 to 100°C |
|
• Comply with |
• EN 60950 • EN 50155 S1 |
|
• Application fiels |
Railway application |