Input |
• Rated input voltage |
90÷264Vac |
|
• Line frequency |
50/60Hz |
|
• Leakage current to GND (max) |
Max 2mA at 50Hz |
|
• Input protection |
• Inrush current limitation• EMI filter and line fuse• Input undervoltage prot. |
Output |
• Output voltage |
See datasheet |
|
• Output voltage temp drift |
0.05%/°C |
|
• Output voltage long term stability |
Better than 1% after 24 hours |
|
• Output power (max) |
40W |
|
• Temp power derating |
2%/°C (50÷70°C) |
|
• Hold up time |
15msec min. |
|
• Output protections |
• Overload protection on all outputs• Short circuit protection on all outputs• Overvoltage: on output A at Vo + 25% typ. |
General Features |
• DC-DC / AC-DC |
AC - DC |
|
• Efficiency |
75% typ. |
|
• Dieletric withstand voltage |
• Input - Output: 3750Vac (on insul.comp.)• Input - P.E.: 1750Vac |
|
• Isolation |
• Output - P.E.: 500Vdc |
|
• See table for |
• Output voltages and currents• Line regulation (min÷max)Vin• Load regulation (10÷100%)Iout• Output ripple (0÷20MHz) |
|
• Cooling |
Natural convection |
|
• Other features |
Optional:• C - Closed box• H - RAIL-DIN mounting• PF - Power fail/reset signals |
|
• Operating temperature |
0°C to 50°C |
|
• Storage temperature |
"-20°C to 85°C" |
|
• Switching frequency |
60KHz ca. |
|
• Weight |
open-frame: 440g, closed: 660g |
|
• Comply with |
• EN 50081-1• EN 61000-6-2• EN 60950-1• CE |
|
• Dimensions |
100x160x40 |
|
• Application fiels |
Industrial Application |