Input |
• Rated input voltage |
@220Vac/230Vac Input voltage tolerance.5% Input frequency tolerance 2% Input voltage distorsion 5% |
|
• Line frequency |
50Hz |
|
• Power factor |
>0.6 |
|
• Input protection |
• EMI filter • Inrush current protection • Fuse on input line (on front panel) • Fuse on input signal 12V (Power ON) |
|
• Input inhibit |
• Input signal 12V to switch on the PSU (active low) |
|
• Input connections |
DIN41612 tipo C 64p M90° |
Output |
• Adjustable voltage range |
• Outputs selectable by jumpers 150/155Vac |
|
• Output power (max) |
230VA |
|
• Hold up time |
>20ms (turn off time <20ms) |
|
• Start up time |
100ms < t < 150ms ( 90%Vout nom.) |
|
• Rise time |
< 10ms (10%Vout nom. - 90%Vout nom.) |
|
• Output protections |
• Vout max = 150Vac +5% (duty-cycle max) • Fuses on all outputs (T 1A) on front panel |
|
• Output signals |
• ALARM SIGNAL: • 0V (COM_12V) if one or more outputs fail. • Open collector if all outputs are ok. |
|
• Output connections |
DIN 41612 tipo E 48p M90° |
General Features |
• Dieletric withstand voltage |
• Input - 12Vdc : 3500Vac • Input - Output : 3500Vac • 12Vdc - Output : 3500Vac • Output - output : 3500Vac |
|
• Isolation |
• Input - 12Vdc : 7mm • Input - Output : 7mm • 12Vdc - Output : 7mm • Output - output : 7mm |
|
• Cooling |
Natural cooling |
|
• Operating indicator |
• Green LED on each output front panel. • Green LED Input presence 220Vac. • Green LED Input signal Presence 12V. |
|
• Operating temperature |
-25°C to +70°C |
|
• Storage temperature |
-25°C to +85°C |
|
• Comply with |
• CENELEC EN50129 • EN 50124-1 • FSIS402 • CENELEC EN 50121-4 • CENELEC EN 50125-3 • CENELEC EN 60950-1 • CEE 73/23 • CE |