Input |
• Rated input voltage |
16,8÷36 (24Vdc Nom.) 14,4÷40Vdc ( for 0.1 sec.) |
|
• Input protection |
• Inrush current limitation • RFI filter • Fuse |
|
• Output voltage temp drift |
0.02%/°C |
|
• Output voltage long term stability |
Better than 1% after 24 hours |
Output |
• Output power (max) |
50 W (75 W peak) |
|
• Hold up time |
10ms at Pout = 50W |
|
• Output protections |
• Over voltage protection • Short circuit protection • Over current protection |
General Features |
• DC-DC / AC-DC |
DC - DC |
|
• Efficiency |
75% typ. |
|
• Dieletric withstand voltage |
• Input - P.E.: 1000Vac • Output - P.E.: 500Vac |
|
• Isolation |
• Output - P.E.: R > 100MOhm |
|
• See table for |
• Output voltages and currents • Tolerance (line+load reg) • Ripple and noise |
|
• Cooling |
Natural convection |
|
• Operating temperature |
-40°C to 85°C |
|
• Switching frequency |
70KHz typ. |
|
• Comply with |
• EN 50155:2007 • EN 50121.3-2:2007 • CEI-IEC 61373:1999 • CE |