Input |
• Rated input voltage |
230 Vac (176÷264 Vac) |
|
• Line frequency |
50Hz +-5% |
|
• Input current (max) |
3 A Max |
|
• Leakage current to GND (max) |
Max 2mA at 50Hz |
|
• Input protection |
• Inrush current limitation : 30A at Vin=230Vac • EMI filter • Line fuse T6,3A 250V |
|
• Output voltage temp drift |
0.01%/°C |
Output |
• Remote sense compensation |
0.5V max |
|
• Output power (max) |
280W |
|
• Test points |
Output voltage test-points |
|
• Output protections |
• Overload protection • Short circuit protection • Overvoltage: at Vo + 25% typ. |
|
• Output signals |
• Alarm relay contact (U.V.P) |
General Features |
• DC-DC / AC-DC |
AC - DC |
|
• Efficiency |
88% typ. |
|
• Dieletric withstand voltage |
• Input - P.E.: 1500Vac • Output - P.E.: 500Vdc |
|
• See table for |
• Output voltages and currents • Line and load regulation • Output ripple and noise |
|
• Cooling |
Natural convection |
|
• Operating indicator |
• Led Vout OK on front panel |
|
• Other features |
Optional features • DD - Output decoupling diode for parallel connection • AL - Alarm relay contact (0,75Vn ±10%) |
|
• Operating temperature |
-25°C to +70°C |
|
• Storage temperature |
-40°C to +85°C |
|
• Weight |
1660g |
|
• Comply with |
• EN 60950-1 • EN 55011 • EN 61000-4-2 • EN 61000-4-3 • EN 61000-4-4 • EN 61000-4-5 • EN 61000-4-6 • IEC 60068-2-6 |