Input |
• Rated input voltage |
Input V1 90÷264Vac Input V2 24Vdc (18-32Vdc) |
|
• Line frequency |
47 - 63Hz (V1) |
|
• Leakage current to GND (max) |
Max 1mA at 50Hz |
|
• Input protection |
• Fuses • Mains filter • Inrush current limitation • Soft start |
|
• Output voltage long term stability |
Better than 1% after 24 hours |
Output |
• Output power (max) |
12W |
|
• Output protections |
• Over load • Short circuit |
General Features |
• DC-DC / AC-DC |
AC - DC |
|
• Efficiency |
82% typ. |
|
• Dieletric withstand voltage |
• AC Input - Output : 1750Vac • Output - P.E. : 500Vac |
|
• See table for |
• Output voltages and currents • Line and load regulation • Output ripple and noise |
|
• Cooling |
Natural convection |
|
• Operating temperature |
-40°C to +55°C |
|
• Storage temperature |
-40°C to +85°C |
|
• Comply with |
• EN 61000-6-4• EN 61000-6-2• EN 60950-1• CE |
|
• Application fiels |
Military Application |