Input |
• Rated input voltage |
48V nominali (36÷75Vdc) |
|
• Input protection |
• Fuse inside • RFI filter |
|
• Output voltage temp drift |
0.01%/°C |
|
• Output voltage long term stability |
Better than 1% after 24 hours |
Output |
• Output power (max) |
125W |
|
• Output protections |
• Over load protection • Short circuit protection• Crow-bar • Power off for over and under voltage • Over temperature protection |
General Features |
• DC-DC / AC-DC |
DC - DC |
|
• Efficiency |
87% @ 48V |
|
• Dieletric withstand voltage |
• Input - P.E. > 500Vdc |
|
• Isolation |
• Output - P.E. > 500Vdc |
|
• See table for |
• Output voltages and currents • Line and load regulation • Output ripple and noise |
|
• Cooling |
Natural convection on front panel |
|
• Operating indicator |
• Gren led on for operating ok |
|
• Operating temperature |
-10°C to 55°C |
|
• Storage temperature |
-40°C to 85°C |
|
• Comply with |
• EN 60950-1 • CE |