Input |
• Rated input voltage |
Nominal:128 Vdc Range:89,6…160 Vdc (76,8…179,2Vdc 0,1sec.) |
|
• Input protection |
• Inrush current typ. < 30A @ Vin max, cold-start. |
|
• Output voltage temp drift |
0.01%/°C typ |
|
• Output voltage long term stability |
Better than 1% after 24hours typ. |
Output |
• Output power (max) |
960W |
|
• Temp power derating |
1%/°C (50÷70°C) |
|
• Start up time |
<0.5 sec. |
|
• Output protections |
• Short circuit protection with automatic restart • Overcurrent protection: 1,1÷1,5 In • Overvoltage protection: 1,25÷1,40 Vn |
General Features |
• Efficiency |
90% |
|
• Dieletric withstand voltage |
• Conform to EN 60950-1 |
|
• Isolation |
• Output - P.E.: 500Vdc |
|
• See table for |
• Output voltage and current • Output ripple and noise |
|
• Cooling |
Natural convention |
|
• Operating indicator |
• Led Vout OK |
|
• Other features |
Optional features • DD - Output decoupl. diode for parallel connection • AL - Alarm relay contact |
|
• Operating temperature |
-25°C to 85°C -25°C to +50°C (without additional heatsink) |
|
• Storage temperature |
-40°C to 85°C |
|
• Switching frequency |
50KHz typ. |
|
• Weight |
4,75Kg. |
|
• Comply with |
• EN 50155 • EN 50121-4 • EN 50121-3-2 • EN 60950-1 • CE |