Input |
• Rated input voltage |
115 - 230 V (90 ÷ 264 Vac) |
|
• Line frequency |
50-60 Hz (47÷63 Hz) |
|
• Input current (max) |
2,5 A Max |
|
• Power factor |
=> 0,9 |
|
• Leakage current to GND (max) |
< 3,5mA-rms at 250 Vac, 50 Hz |
|
• Input protection |
• Fuses for Input Overcurrent Protection • EMI filter • Inrush Current Limitation • Input Undervoltage Protection |
|
• Input inhibit |
• PS_ON# is an active low. (when the signal is pulled to TTL low, the outputs is on expect +5 VSB which is always enable whenever the AC power is present.) |
Output |
• Output power (max) |
Max 140W |
|
• Temp power derating |
2%/°C (50÷70°C) |
|
• Hold up time |
> 16 ms |
|
• Start up time |
< 500 ms |
|
• Rise time |
0,2 ÷ 20 ms |
|
• Output protections |
• Short circuit protection • Overload protection • Overtemperature protection |
|
• Output signals |
• PWR_OK is a "power good" = high when all outputs are OK. (Logic Level high = 2,4 ÷ 5V) • PWR_OK Delay = 0,2 ÷ 20 ms • PWR_OK Rise Time < 10ms • AC loss to PWR_OK > 16ms |
General Features |
• DC-DC / AC-DC |
AC - DC |
|
• Efficiency |
85% (typ.@Pout=nominal) |
|
• Dieletric withstand voltage |
• Input - Output = comply with EN 60950-1 • Input - P.E. = comply with EN 60950-1 • Output - P.E. = comply with EN 60950-1 |
|
• Isolation |
• Input - P.E. > 200 MOhm • Output - P.E. > 200 Mohm |
|
• See table for |
• Output voltages and currents • Line and load regulation • Output ripple and noise • Capacitive loading |
|
• Cooling |
External ventilation required. |
|
• MTBF |
• (MIL-HDBK-217F) 150,000 hours of continuous operation at 55° C, maximum-output load and nominal AC input voltage. |
|
• Operating temperature |
0 ÷ +70 °C |
|
• Storage temperature |
-20° ÷ +80° C |
|
• Humidity |
Operating : 20÷90% RH, Non-condensing Storage : 10÷95% RH, Non-condensing |
|
• Switching frequency |
60KHz typ. |
|
• Comply with |
Conducted emissions • EN 61204-3 - EN 55011 Radiated emissions • EN 61204-3 - EN 55022 Limits for harmonic current emission • EN 61204-3 - EN 61000-3-2 - class A Voltage fluctation and flicker • EN 61204-3 - EN 61000-3-3 Radio frequency amplitude modulated electromagnetic field • EN 61204-3 - EN 61000-4-3 Power frequency magnetic field immunity • EN 61204-3 - EN 61000-4-8 Electrostatic discharge immunity • EN 61204-3 - EN 61000-4-2 - level 4 Conducted immunity • EN 61204-3 - EN 61000-4-6 Electric fast transient immunity • EN 61204-3 - EN 61000-4-4 Surge Immunity • EN 61204-3 - EN 61000-4-5 Voltage dips and immunity • EN 61204-3 - EN 61000-4-11 Safety • EN 60950-1 • UL 60950-1 ed. 2006 • CAN/CSA-C22,2N° 60950-1-03 • ROHS • CE U.S.A. and CANADA • FCC part 15 class B |