SD208-I2-X

Railway Application Single output DC-DC converter with I/O isolation Signaling Equipment

Input • Rated input voltage 18÷36Vdc
• Input protection • Input line fuse F 20A • Input voltage polarity inversion through parallel diode
Output • Output power (max) 180Wmax
• Parallel connection With output decoupling diode
• Output protections • Over current protection • Short circuit protection • Over voltage protection • Over temp.
General Features • Isolation • Input - (Output - P.E.): 1000Vdc
• See table for • Output voltage and current • Line and load regulation • Ripple and noise
• Cooling Natural convection
• Operating temperature -25°C to 85°C
• Storage temperature -40°C to 85°C
• Comply with • EN50155 • EN 50081-1 • EN 50082-1 • EN 60950 • CE
• Dimensions 198x108x58
• Application fiels Railway Application