140W / AC - DC

Industrial Application Multi output AC-DC power supply unit

Input • Rated input voltage 115 - 230 V (90 ÷ 264 Vac)
• Line frequency 50-60 Hz (47÷63 Hz)
• Input current (max) 2,5 A Max
• Power factor => 0,9
• Leakage current to GND (max) < 3,5mA-rms at 250 Vac, 50 Hz
• Input protection • Fuses for Input Overcurrent Protection • EMI filter • Inrush Current Limitation • Input Undervoltage Protection
• Input inhibit • PS_ON# is an active low. (when the signal is pulled to TTL low, the outputs is on expect +5 VSB which is always enable whenever the AC power is present.)
Output • Output power (max) Max 140W
• Temp power derating 2%/°C (50÷70°C)
• Hold up time > 16 ms
• Start up time < 500 ms
• Rise time 0,2 ÷ 20 ms
• Output protections • Short circuit protection • Overload protection • Overtemperature protection
• Output signals • PWR_OK is a "power good" = high when all outputs are OK. (Logic Level high = 2,4 ÷ 5V) • PWR_OK Delay = 0,2 ÷ 20 ms • PWR_OK Rise Time < 10ms • AC loss to PWR_OK > 16ms
General Features • DC-DC / AC-DC AC - DC
• Efficiency 85% (typ.@Pout=nominal)
• Dieletric withstand voltage • Input - Output = comply with EN 60950-1 • Input - P.E. = comply with EN 60950-1 • Output - P.E. = comply with EN 60950-1
• Isolation • Input - P.E. > 200 MOhm • Output - P.E. > 200 Mohm
• See table for • Output voltages and currents • Line and load regulation • Output ripple and noise • Capacitive loading
• Cooling External ventilation required.
• MTBF • (MIL-HDBK-217F) 150,000 hours of continuous operation at 55° C, maximum-output load and nominal AC input voltage.
• Operating temperature 0 ÷ +70 °C
• Storage temperature -20° ÷ +80° C
• Humidity Operating : 20÷90% RH, Non-condensing Storage : 10÷95% RH, Non-condensing
• Switching frequency 60KHz typ.
• Comply with Conducted emissions • EN 61204-3 - EN 55011 Radiated emissions • EN 61204-3 - EN 55022 Limits for harmonic current emission • EN 61204-3 - EN 61000-3-2 - class A Voltage fluctation and flicker • EN 61204-3 - EN 61000-3-3 Radio frequency amplitude modulated electromagnetic field • EN 61204-3 - EN 61000-4-3 Power frequency magnetic field immunity • EN 61204-3 - EN 61000-4-8 Electrostatic discharge immunity • EN 61204-3 - EN 61000-4-2 - level 4 Conducted immunity • EN 61204-3 - EN 61000-4-6 Electric fast transient immunity • EN 61204-3 - EN 61000-4-4 Surge Immunity • EN 61204-3 - EN 61000-4-5 Voltage dips and immunity • EN 61204-3 - EN 61000-4-11 Safety • EN 60950-1 • UL 60950-1 ed. 2006 • CAN/CSA-C22,2N° 60950-1-03 • ROHS • CE U.S.A. and CANADA • FCC part 15 class B


Power Control Systems Italy
Manufactured by: Power Control Systems srl Italy
Model: 140W / AC - DC
Product ID: 140W / AC - DC

For all requests please fill in the following fields below.
Fields with an asterisk are obligatory.

Name *
Surname *
Address
Postal Code
City
Telephone
Fax
E-mail *
Web
Request *
According to the law of 13 D.lgs. 196/ 2003.
I declare to have read the general regulations that pertain to privacy laws

Made by Bo.Di.